Two capsules can hold the same amount of an ingredient and still give very different concentrations in the blood. This simulator uses the standard one-compartment model to show how much of a dose reaches the blood, and how fast, change the curve.

Educational model, not a dose guide. The parameters are hypothetical and describe no product, ingredient or person. Real compounds, botanical ones especially, often break the model’s assumptions (see the limits below).

Simulator 1

Two formulations of the same dose

Formulation A and formulation B contain the same dose and share the same body: clearance and volume of distribution. They differ in the fraction that reaches the blood (bioavailability, F) and in how fast it is absorbed (ka).

C(t) = F·D·ka / [V·(ka − k)] · (e−k·t − e−ka·t),  k = CL / V
Formulation A
Formulation B
Shared: dose and the body

Plasma concentration after one oral dose, formulations A and B

  • Formulation A (solid)
  • Formulation B (dashed)
Half-life, both3.47 h
Peak Cmax, A–
Peak Cmax, B–
Time of peak, A · B–
Exposure AUC, A · B–
B relative to A: AUC · Cmax–

Doubling F doubles exposure. A faster absorption rate raises and advances the peak without changing exposure.

Show the curves as a table
Modeled concentration at selected times
Time, hA, mg/LB, mg/L
000
Simulator 2

Where an oral dose is lost before it reaches the blood

Oral bioavailability is the product of three fractions: the fraction absorbed from the gut (Fa), the fraction escaping elimination in the gut wall (Fg) and the fraction escaping elimination in the liver on the first pass (Fh). Each loss multiplies the next, so three moderate losses add up to a large one.

F = Fa × Fg × Fh
Fractions, %
Dose swallowed100%
After the gut60%
After the gut wall42%
Reaches the blood, F21%

A release or simulated-digestion test shows how much is freed from the product in the gut (bioaccessibility). That is a precondition for Fa, not a measure of F: dissolved compound can still fail to cross the gut wall or be metabolized on the way. How digestion works

Method

Equations, assumptions and limits

Model
One well-mixed compartment, first-order absorption and first-order elimination after a single oral dose.
Equations
k = CL/V; t½ = ln 2/k; C(t) = F·D·ka/[V(ka − k)]·(e−kt − e−kat); when ka = k, C(t) = F·D·k·t·e−kt/V; tmax = ln(ka/k)/(ka − k); AUC0–∞ = F·D/CL; F = Fa·Fg·Fh.
What follows from them
Exposure (AUC) depends on F, dose and clearance, not on ka or V; so B’s AUC relative to A’s equals FB/FA. The absorption rate changes the height and timing of the peak. When absorption is slower than elimination (ka < k), the decline after the peak reflects absorption (“flip-flop” kinetics).
Units
Dose in mg, CL in L/h and V in L give concentration in mg/L (equal to µg/mL); time in hours.
Assumptions
Linear kinetics; no lag time; the same clearance and volume for both formulations; parent compound only.
Limits
It describes no real ingredient. Many botanical constituents are extensively metabolized, so most of what circulates is metabolites, which this model ignores; the same F can come from different combinations of Fa, Fg and Fh; higher blood levels do not by themselves mean a larger benefit or a safe intake.
Sources
Grogan S, Preuss CV. Pharmacokinetics. StatPearls, updated July 30, 2023 (half-life, volume, clearance, bioavailability). Mould DR, Upton RN. CPT Pharmacometrics Syst Pharmacol 2013;2:e38 (first-order absorption; flip-flop kinetics). Varma MVS, Obach RS, Rotter C, et al. J Med Chem 2010;53:1098–1108 (oral bioavailability as the product of Fa, Fg and Fh). The remaining expressions follow algebraically. The same model, with repeated doses, is on ADME and pharmacokinetics.

Health information notice

These statements have not been evaluated by the Food and Drug Administration. Nothing on this site is intended to diagnose, treat, cure or prevent any disease. The information is for general education only. It is not medical advice and does not replace advice, diagnosis or treatment from a qualified health professional, or any medication a clinician has prescribed.

Do not start, stop or change any medicine, supplement or herbal product because of something you read here. Talk to your doctor or pharmacist first, especially if you are pregnant or breastfeeding, have a medical condition, take any medicines, are preparing for surgery, or are caring for a child. Research findings, traditional uses and safety data are reported as their sources state them; they are not recommendations or claims about any product. If you think you may have a medical emergency, call your doctor or 911 at once.

EUTECNIQ Sciences sells no supplements or health products today and receives nothing from any product or ingredient mentioned on this site; any commercial interest it later has in an ingredient will be stated on that ingredient’s page.

Ready to check what you take?

Free tools built on published reference values, each with its sources and its limits. Your lists stay in your browser.