EUTECNIQ Sciences

See every page on one mapArrow keys move through results · Enter opens · Esc closes

Capabilities · Process engineering

Exergy shows where a process destroys the value of its heat

An energy balance closes even when a process wastes most of what its steam could do. Exergy is the part of energy that can still do useful work, and every real process destroys some of it. In one illustrative solvent-recovery step, the evaporator and condenser destroy 79% of the steam's exergy, a loss the energy balance cannot show.

Proposed capabilityEUTECNIQ has analyzed no plant and holds no plant data. The example uses the illustrative stream table of the process-engineering page, hypothetical operating values and CoolProp 8.0.0 reference properties.

One solvent-recovery step, per illustrative batch Steam energy and steam exergy drawn to one scale, MJ

Energy and exergy of the steam used by the solvent-recovery stepPer illustrative batch at the page's default inputs. Energy view: the steam brings 10,262 MJ of enthalpy above 25 °C; 8,685 MJ (85%) ends in the cooling water and 1,577 MJ (15%) returns with the condensate. Exergy view, same scale: the steam's work potential is 2,311 MJ; 1,430 MJ (62%) destroyed in the evaporator; 391 MJ (17%) destroyed in the condenser; 281 MJ (12%) to the cooling water; 209 MJ (9%) back with the condensate.Energy view: steam enthalpy above 25 °C10,262 MJ per batch8,685 MJ to the cooling water (85%)1,577 MJ back with the condensate (15%)Exergy view: the same steam's work potential2,311 MJ per batch, drawn to the same scale1,430 MJ destroyed in the evaporator (62%)391 MJ destroyed in the condenser (17%)281 MJ to the cooling water (12%)209 MJ back with the condensate (9%)
Hypothetical example Computed, not measured. Saturated steam at 200 kPa evaporates 4,080 kg of ethanol and 2,120 kg of water at 50 °C; cooling water warms from 30 to 40 °C; dead state 25 °C and 101.325 kPa. Properties from CoolProp 8.0.0. Every value is in the table in section 03.

01 · The problem

An energy balance can close perfectly while most of the steam's value is lost

Energy is conserved, so a first-law balance can only say where energy leaves a unit. In the evaporator below, every megajoule of steam heat reaches the boiling solvent, which makes the unit look perfect. On the way the heat falls from 120 °C to 50 °C, and that fall destroys 62% of the steam's ability to do work.

Energy

The energy balance blames the cooling water

The steam brings 10,262 MJ of enthalpy above 25 °C per batch. The condenser passes 8,685 MJ, 85% of it, to the cooling water, and the condensate takes the rest back. Read this way, the cooling water is the loss to attack.

Exergy

The exergy balance finds the loss inside the units

The same steam can do at most 2,311 MJ of work, 23% of its enthalpy. The evaporator destroys 1,430 MJ of it and the condenser 391 MJ. The cooling water carries away only 281 MJ, and the condensate returns 209 MJ to the boiler.

Decision

The two balances point to different fixes

Recovering condenser heat saves energy on paper, but heat at 40 °C carries little exergy. The larger loss is the temperature gap in the evaporator, which a second effect, vapor recompression or heat integration can put to use.

Next: the six terms behind these numbers.

02 · Definitions

Six terms carry the whole method

Exergy analysis adds an entropy balance to the energy balance and expresses the result as work. Each term below is quoted or transcribed from the source named under it.

1

Exergy

The useful work potential of energy at a given state, measured against the surroundings. Energy is conserved; exergy is consumed by every real process. For a flowing stream, neglecting kinetic and potential energy:

e = (h − h0) − T0(s − s0)

Heat Q available at absolute temperature T carries exergy Q(1 − T0/T). Heat near the surroundings' temperature carries almost none.

Published evidence Çengel and Boles, glossary to chapter 8; University of Waterloo ME 354 notes, "Availability".

2

Dead state

The state in thermodynamic equilibrium with the environment, where exergy is zero. The usual choice is T0 = 25 °C and p0 = 1 atm (101.325 kPa); this page uses it and shows in section 05 what changes when T0 moves.

Published evidence Çengel and Boles; Waterloo ME 354 notes; da Silva et al. 2012.

3

Physical and chemical exergy

Physical exergy comes from a stream's temperature and pressure differing from T0 and p0; it splits into a thermal and a mechanical part. Chemical exergy comes from its composition differing from a reference environment, a defined set of reference substances proposed by Szargut. Liquid ethanol's standard chemical exergy is 1,357.7 kJ/mol, or 29.5 MJ/kg.

Published evidence Witte et al. 2022, eq. 3–5; Sciubba and Wall 2007; Szargut et al. 1988 as tabulated in TESPy 0.7.6.

4

Exergy destruction (Gouy–Stodola)

Gouy (1889) and Stodola (1898) independently related lost work to entropy generation. Heat transfer across a temperature difference, mixing, friction and throttling all generate entropy, and the work potential lost is

ED = T0 Sgen ≥ 0

Published evidence Sciubba and Wall 2007; Çengel and Boles; da Silva et al. 2012 ("Gouy-Stodola relation").

5

Exergetic efficiency

Each unit consumes a fuel exergy EF to deliver a product exergy EP; the difference is destroyed. For a whole system, losses EL also leave the boundary unused, as the cooling water and condensate do here.

ε = EP/EF · EF = EP + ED + EL

What counts as product is a choice, and it must be stated with the result.

Published evidence Witte et al. 2022, eq. 8–10 (with Tsatsaronis).

6

Grassmann diagram

An exergy flow diagram, named after Grassmann's 1950 work. Each flow is drawn with a width proportional to its exergy, and destruction appears as branches that end inside the units. Section 03 draws one for the example.

Published evidence Sciubba and Wall 2007, footnote 9.

Next: the definitions applied to one evaporator.

03 · Worked example

In one solvent-recovery step, the evaporator and condenser destroy 79% of the steam's exergy

The system is the falling-film evaporator E-101 and the solvent condenser of the illustrative extraction train. Per batch they evaporate and condense 4,080 kg of ethanol and 2,120 kg of water. Change the inputs to see where the destruction goes.

Inputs of the worked example and their status
InputDefaultStatus
Vapor evaporated and condensed per batch4,080 kg ethanol and 2,120 kg water (stream 8)Illustrative balance, process-engineering page
Heating steamSaturated, 200 kPa absolute (120.2 °C), leaves as saturated condensateHypothetical
Evaporating and condensing temperature50 °C, under vacuumHypothetical
Cooling waterEnters 5 K above the dead state (30 °C), leaves 10 K warmer or 5 K below the condensing temperatureHypothetical
Dead state25 °C, 101.325 kPa, liquid waterConvention
Evaporator area readoutOverall coefficient 1,000 W/(m²·K), evaporation over 8 hHypothetical, for comparison only
50
200
0
25

The inputs need JavaScript. The diagram, the readouts and the tables show the default inputs.

Grassmann diagram of the step Band width proportional to exergy, MJ per batch; percentages of the steam's exergy

Grassmann diagram of the solvent-recovery stepExergy per batch, band width proportional to MJ. Steam supplies 2,311 MJ. 209 MJ (9%) returns with the condensate; 1,430 MJ (62%) is destroyed in the evaporator; 672 MJ (29%) reaches the condenser with the vapor, where 391 MJ (17%) is destroyed and 281 MJ (12%) leaves with the cooling water.Evaporator E-101Condenser E-102Steam at 120 °C2,311 MJ · 100%Returned with condensate209 MJ · 9%To the condenser672 MJ · 29%Destroyed in the evaporator1,430 MJ · 62%Destroyed in the condenser391 MJ · 17%Cooling water281 MJ · 12%Grassmann diagram of the solvent-recovery stepExergy per batch, band width proportional to MJ. Steam supplies 2,311 MJ. 209 MJ (9%) returns with the condensate; 1,430 MJ (62%) is destroyed in the evaporator; 672 MJ (29%) reaches the condenser with the vapor, where 391 MJ (17%) is destroyed and 281 MJ (12%) leaves with the cooling water.Steam at 120 °C2,311 MJ · 100%Evaporator E-101Returned with condensate209 MJ · 9%Destroyed in the evaporator1,430 MJ · 62%To the condenser672 MJ · 29%Condenser E-102Destroyed in the condenser391 MJ · 17%Cooling water281 MJ · 12%
Hypothetical example Computed from CoolProp 8.0.0 properties at the inputs above; not plant data. Destruction is the exergy balance of each unit and equals T0Sgen computed from its entropy balance. Condensate and cooling water leave the boundary with exergy that this step does not use.
Values at the default inputs
Energy and exergy per batch at the default inputs
TermEnergy, MJExergy, MJ% of steam exergy
Steam supplied (saturated vapor at 200 kPa)10,2622,311100.0
Returned with the condensate (leaves the boundary)1,5772099.1
Destroyed in the evaporator, T0·Sgen01,43061.9
Carried by the vapor to the condenser8,68567229.1
Destroyed in the condenser, T0·Sgen039116.9
Leaves with the cooling water8,68528112.2

At these inputs the evaporator destroys 62% and the condenser 17% of the steam's exergy; the cooling water carries 12% away.

Heat duty, evaporator and condenser
8,685 MJ
Steam used
3,945 kg at 120.2 °C
Exergy supplied by the steam
2,311 MJ
Destroyed in the evaporator
1,430 MJ, 62%
Destroyed in the condenser
391 MJ, 17%
Destroyed in both units
79% of the steam exergy
Evaporator exergetic efficiency
32%
Step exergetic efficiency, separation plus recovered heat
2.0%
Heat recovered, energy and exergy
0 MJ and 0 MJ (–)
Cooling water
208 t, 30 to 40 °C
Evaporator area at the stated coefficient
4.3 m²

The step's real product is the separation. Its minimum work, for an ideal solution at 25 °C, is 42 MJ per batch, 2.0% of the exergy the steam gives up in the evaporator, which is why the heat chain above can leave it out.

Method, assumptions and limits

What it calculates. Energy and exergy per batch for evaporating and condensing stream 8: the steam's exergy, its split into condensate, destruction in each unit, cooling water and recovered heat; the separation's minimum work; and an evaporator area for comparison.

Equations. Heat duty Q = Σi mi hfg,i(Tb) for ethanol and water. Exergy delivered to the process Ep = Σi mi(hfg,i − T0sfg,i) = Q(1 − T0/Tb). Steam ms = Q/(hg − hf); exergy in ms[(hg − h0) − T0(sg − s0)], condensate likewise with hf, sf. Evaporator destruction = steam exergy in − condensate exergy − Ep. Cooling water mcw = Q/(hout − hin) with exergy gain mcw[(hout − hin) − T0(sout − sin)]; condenser destruction = Ep − that gain. A fraction f of the condenser heat goes to a user at the same temperatures, so f of the gain counts as recovered. Minimum separation work, filtrate liquid to distillate and aqueous concentrate at T0: Wmin = RT0[nDΣx ln x − nFΣx ln x] (activity coefficients set to 1). Area A = Q/[U(Ts − Tb)t].

Variables and units. h kJ/kg, s kJ/(kg·K), temperatures in kelvin inside the equations, results in MJ per batch. Exergetic efficiency of the evaporator: product Ep, fuel = steam exergy in − condensate exergy. Efficiency of the step: product Wmin + recovered exergy, same fuel.

Assumptions. The process side boils and condenses at one temperature; latent heat only (feed already at Tb); ideal mixing, so heat of mixing and the boiling-point spread of ethanol–water are ignored; no heat losses, pressure drops, vacuum-pump work or subcooling. The boiler and the cooling tower are outside the boundary. The extract solids are ignored. The process-engineering page uses latent heats at the normal boiling points (8,200 MJ for this step); at 50 °C both latent heats are larger, giving 8,685 MJ.

Valid range. Inputs are limited to the slider ranges. The condensing temperature must exceed the cooling-water inlet by at least 8 K (3 K of warming and a 5 K approach); below that the model raises it and says so.

What it does not establish. A design, a cost, a saving, a product-quality effect or an environmental impact. Steam and electricity are not compared.

Properties. CoolProp 8.0.0 (Bell et al. 2014): water IAPWS-95 (Wagner and Pruß 2002), ethanol (Schroeder et al. 2014). Water values agree with the NIST Chemistry WebBook to the digits shown; ethanol's enthalpy of vaporization is 0.6% above NIST's tabulated 41.0 kJ/mol at 320 K and 1.3% above 38.7 kJ/mol at 351 K. Tables every 2.5 kPa and 0.5 °C, interpolated linearly.

Verification. An independent script evaluates the model directly in CoolProp, checks each destruction against T0Sgen from the entropy balance, renders the diagram with this page's own script at 193 input sets and checks every label. A second script runs the page model on 13 input sets and passes when every result agrees within 0.5%.

Next: what moves the loss and what removes it.

04 · Where destruction concentrates

Changing the vacuum moves the destruction between units without reducing it

Raising the process temperature from 50 to 80 °C cuts evaporator destruction from 1,430 to 721 MJ and raises condenser destruction from 391 to 1,030 MJ. With the cooling water fixed at 30 to 40 °C, 78.8% of the steam's exergy is destroyed at every temperature from 50 to 80 °C. At 40 °C the share rises to 81.7%, because the cooling water must leave cooler.

Steam exergy split at five process temperatures MJ per batch; steam at 200 kPa, dead state 25 °C; number above each bar: MJ destroyed in both units

Exergy destroyed as the process temperature changesSteam exergy per batch split four ways at process temperatures of 40 to 80 °C (steam at 200 kPa, dead state 25 °C). 40 °C: evaporator 1,706, condenser 205, cooling water 215, condensate 212, total destroyed 1,911 MJ; 50 °C: evaporator 1,430, condenser 391, cooling water 281, condensate 209, total destroyed 1,821 MJ; 60 °C: evaporator 1,175, condenser 624, cooling water 278, condensate 207, total destroyed 1,799 MJ; 70 °C: evaporator 939, condenser 836, cooling water 274, condensate 204, total destroyed 1,775 MJ; 80 °C: evaporator 721, condenser 1,030, cooling water 270, condensate 201, total destroyed 1,751 MJ.05001,0001,5002,0002,500MJ per batch1,911 destroyed40 °C1,821 destroyed50 °C1,799 destroyed60 °C1,775 destroyed70 °C1,751 destroyed80 °CExergy destroyed as the process temperature changesSame data as the wide chart: 40 °C: evaporator 1,706, condenser 205, cooling water 215, condensate 212 MJ; 50 °C: evaporator 1,430, condenser 391, cooling water 281, condensate 209 MJ; 60 °C: evaporator 1,175, condenser 624, cooling water 278, condensate 207 MJ; 70 °C: evaporator 939, condenser 836, cooling water 274, condensate 204 MJ; 80 °C: evaporator 721, condenser 1,030, cooling water 270, condensate 201 MJ.40 °C: 1,911 MJ destroyed (82%)evaporator 1,706 · condenser 20550 °C: 1,821 MJ destroyed (79%)evaporator 1,430 · condenser 39160 °C: 1,799 MJ destroyed (79%)evaporator 1,175 · condenser 62470 °C: 1,775 MJ destroyed (79%)evaporator 939 · condenser 83680 °C: 1,751 MJ destroyed (79%)evaporator 721 · condenser 1,030
Hypothetical example Same model and inputs as section 03, process temperature varied. The area column assumes the stated coefficient and 8 h of evaporation.
Values in the chart
Steam exergy split at five process temperatures
Process temperatureEvaporator destroyed, MJCondenser destroyed, MJCooling water, MJCondensate, MJTotal destroyed, MJEvaporator area, m²
40 °C1,7062052152121,9113.8
50 °C1,4303912812091,8214.3
60 °C1,1756242782071,7994.9
70 °C9398362742041,7755.9
80 °C7211,0302702011,7517.2
Steam

Use the coolest steam that does the job

Steam at 150 kPa (111.3 °C) instead of 200 kPa cuts evaporator destruction from 1,430 to 1,279 MJ. It also narrows the temperature gap, so the same duty needs 4.9 m² instead of 4.3 m².

Vapor

Reuse the vapor's exergy

The vapor leaves the evaporator carrying 672 MJ of exergy at 50 °C. A second effect, vapor recompression or heat integration can use part of the gap a single effect destroys; pinch analysis sets the heat-recovery target.

Condenser

Condenser heat is mostly energy, little exergy

Sending half the condenser heat to a low-temperature user recovers 4,343 MJ of energy and 141 MJ of exergy, 3.2% as much. It pays only where something needs heat at about 40 °C.

Solvent

Vented solvent is an exergy loss too

The 30 kg of ethanol vented per batch in the illustrative balance carry 884 MJ of chemical exergy, equal to 38% of the steam's exergy for this step. Better vent condensing may matter more than either heat exchanger.

Model of section 03; vent mass from stream 19 of the illustrative balance; ethanol 1,357.7 kJ/mol (Szargut et al. 1988, via TESPy 0.7.6) and 46.068 g/mol.

Next: the choices behind these numbers.

05 · Limitations

Exergy results depend on choices that must be stated with them

Dead state

The reference temperature changes the answer

Moving T0 from 15 to 35 °C lowers the steam's exergy from 2,581 to 2,047 MJ and the evaporator's exergetic efficiency from 40% to 21%. Sciubba and Wall note that exergy values depend on the reference state chosen, and da Silva et al. that no standard environment fits every region. Options must be compared at one stated dead state.

Results at three dead-state temperatures
T0Steam exergy, MJEvaporator destroyed, MJCondenser destroyed, MJEvaporator ε
15 °C2,5811,38265040%
25 °C2,3111,43039132%
35 °C2,0471,47819721%
Mixtures

A botanical extract has no tabulated chemical exergy

Standard chemical exergies exist for defined compounds such as ethanol. An extract is a mixture of many compounds, some unidentified. Correlations from elemental analysis agree with the Szargut–Styrylska correlations within about ±1.5% for solid fuels (Song et al. 2012), but they estimate a fuel-like work potential and inherit the limits of the heating-value correlations behind them. That number says nothing about an extract's quality, so this page leaves the extract out.

Cost

Less destruction usually means more equipment

Destruction in the evaporator falls as the temperature gap narrows, and the area needed grows: 7.2 m² at 80 °C against 4.3 m² at 50 °C here. Whether that pays depends on steam price, capital cost and product limits. Exergoeconomic methods attach costs to exergy flows for this trade-off (Sciubba and Wall 2007).

Steam pressure, destruction and area
Steam pressureSteam temperatureEvaporator destroyed, MJEvaporator area, m²
150 kPa111.3 °C1,2794.9
200 kPa120.2 °C1,4304.3
400 kPa143.6 °C1,8003.2
Impact

Exergy is not an environmental impact score

Dewulf et al. (2008) found exergy most mature in environmental analysis as resource and efficiency accounting, and far less mature where it is coupled with economics. Sciubba and Wall call the equation "exergy discharge into the environment = pollution" incorrect in quantitative terms. Toxicity and other impacts need life-cycle assessment.

The example is a single-temperature, latent-heat model with ideal mixing and no losses, boiler or cooling tower. It shows the method and the scale of each term; it is not a design.

Next: how EUTECNIQ proposes to use the method.

06 · Proposed use

Exergy would rank where to look; cost, life-cycle impact and product quality would decide

EUTECNIQ proposes to use exergy analysis to screen process options for botanical extraction, solvent recovery and drying, alongside economics and life-cycle assessment. It would never be the sole criterion for a decision.

Proposed capabilityNo client work, plant data or pilot runs exist. Pilot extraction, solvent recovery and drying are planned for Phase II of the facility plan.

  1. Close the balances. Mass and energy first, from the process flow diagram and stream table.
  2. State the frame. Dead state, system boundary, property sources, and the fuel and product of each unit.
  3. Rank the destruction. By unit, with a Grassmann diagram; pinch analysis for heat-recovery targets and CFD where a local flow or heat-transfer mechanism explains a loss.
  4. Screen the options. Exergy, cost drivers (area, steam, solvent makeup), life-cycle indicators and product limits such as maximum temperature in one table, as in the extraction decision demonstration.
  5. Replace the hypotheticals. Measured pilot data before any recommendation.

08 · Sources

References opened for this page

  1. Çengel YA, Boles MA. Thermodynamics: An Engineering Approach. 8th ed. McGraw-Hill; 2015. Online Learning Center, chapter 8 glossary (exergy, dead state, exergy destroyed, second-law efficiency). highered.mheducation.com/sites/0073398179
  2. University of Waterloo. ME 354, Thermodynamics 2: "Availability" lecture notes (flow exergy, exergy of heat, T0 = 25 °C and P0 = 1 atm). mhtlab.uwaterloo.ca/courses/me354
  3. Sciubba E, Wall G. A brief commented history of exergy from the beginnings to 2004. Int J Thermodyn. 2007;10(1):1–26. dergipark.org.tr/en/download/article-file/65698
  4. Witte F, Hofmann M, Meier J, Tuschy I, Tsatsaronis G. Generic and open-source exergy analysis: extending the simulation framework TESPy. Energies. 2022;15(11):4087. doi.org/10.3390/en15114087
  5. da Silva JAM, de Oliveira Junior S, Pulgarín León J, Velazquez Arredondo HI, Molina A. On the exergy determination for petroleum fractions and separation processes efficiency. Proceedings of ENCIT 2012, 14th Brazilian Congress of Thermal Sciences and Engineering; 2012. abcm.org.br/anais/encit/2012
  6. Szargut J, Morris DR, Steward FR. Exergy Analysis of Thermal, Chemical, and Metallurgical Processes. Hemisphere; 1988. Standard chemical exergies as tabulated in the open-source TESPy 0.7.6 dataset tespy/data/ChemEx/Szargut1988.json (ethanol, liquid, 1,357.7 kJ/mol). pypi.org/project/tespy/0.7.6
  7. Song G, Xiao J, Zhao H, Shen L. A unified correlation for estimating specific chemical exergy of solid and liquid fuels. Energy. 2012;40:164–173. doi.org/10.1016/j.energy.2012.02.016
  8. Dewulf J, Van Langenhove H, Muys B, Bruers S, Bakshi BR, Grubb GF, Paulus DM, Sciubba E. Exergy: its potential and limitations in environmental science and technology. Environ Sci Technol. 2008;42(7):2221–2232. doi.org/10.1021/es071719a
  9. Larsen D, ed. Physical Chemistry (LibreTexts), section 24.9: Gibbs energy of mixing of binary solutions in terms of the activity coefficient. CC BY-NC-SA 4.0. chem.libretexts.org, section 24.9
  10. Bell IH, Wronski J, Quoilin S, Lemort V. Pure and pseudo-pure fluid thermophysical property evaluation and the open-source thermophysical property library CoolProp. Ind Eng Chem Res. 2014;53(6):2498–2508. doi.org/10.1021/ie4033999
  11. Wagner W, Pruß A. The IAPWS formulation 1995 for the thermodynamic properties of ordinary water substance for general and scientific use. J Phys Chem Ref Data. 2002;31(2):387–535. doi.org/10.1063/1.1461829
  12. Schroeder JA, Penoncello SG, Schroeder JS. A fundamental equation of state for ethanol. J Phys Chem Ref Data. 2014;43(4):043102. doi.org/10.1063/1.4895394
  13. NIST Chemistry WebBook, SRD 69: thermophysical properties of water (saturation at 200 kPa; liquid at 25 and 35 °C) and ethanol phase-change data (enthalpy of vaporization, Counsell et al. 1970). Retrieved November 1, 2026. webbook.nist.gov

Health information notice. These statements have not been evaluated by the Food and Drug Administration. Nothing on this site is intended to diagnose, treat, cure or prevent any disease, and nothing here is medical advice.

Read the full notice

The information is for general education only. It does not replace advice, diagnosis or treatment from a qualified health professional, or any medication a clinician has prescribed. Do not start, stop or change any medicine, supplement or herbal product because of something you read here. Talk to your doctor or pharmacist first, especially if you are pregnant or breastfeeding, have a medical condition, take any medicines, are preparing for surgery, or are caring for a child. Research findings, traditional uses and safety data are reported as their sources state them; they are not recommendations or claims about any product. If you think you may have a medical emergency, call your doctor or 911 at once.

EUTECNIQ Sciences sells no supplements or health products today and receives nothing from any product or ingredient mentioned on this site; any commercial interest it later has in an ingredient will be stated on that ingredient’s page.

Ready to start a development project?

Tell us about an ingredient you want to specify, verify or license. Questions? Email [email protected]