Capabilities · Process engineering
Exergy shows where a process destroys the value of its heat
An energy balance closes even when a process wastes most of what its steam could do. Exergy is the part of energy that can still do useful work, and every real process destroys some of it. In one illustrative solvent-recovery step, the evaporator and condenser destroy 79% of the steam's exergy, a loss the energy balance cannot show.
Proposed capabilityEUTECNIQ has analyzed no plant and holds no plant data. The example uses the illustrative stream table of the process-engineering page, hypothetical operating values and CoolProp 8.0.0 reference properties.
One solvent-recovery step, per illustrative batch Steam energy and steam exergy drawn to one scale, MJ
01 · The problem
An energy balance can close perfectly while most of the steam's value is lost
Energy is conserved, so a first-law balance can only say where energy leaves a unit. In the evaporator below, every megajoule of steam heat reaches the boiling solvent, which makes the unit look perfect. On the way the heat falls from 120 °C to 50 °C, and that fall destroys 62% of the steam's ability to do work.
The energy balance blames the cooling water
The steam brings 10,262 MJ of enthalpy above 25 °C per batch. The condenser passes 8,685 MJ, 85% of it, to the cooling water, and the condensate takes the rest back. Read this way, the cooling water is the loss to attack.
The exergy balance finds the loss inside the units
The same steam can do at most 2,311 MJ of work, 23% of its enthalpy. The evaporator destroys 1,430 MJ of it and the condenser 391 MJ. The cooling water carries away only 281 MJ, and the condensate returns 209 MJ to the boiler.
The two balances point to different fixes
Recovering condenser heat saves energy on paper, but heat at 40 °C carries little exergy. The larger loss is the temperature gap in the evaporator, which a second effect, vapor recompression or heat integration can put to use.
02 · Definitions
Six terms carry the whole method
Exergy analysis adds an entropy balance to the energy balance and expresses the result as work. Each term below is quoted or transcribed from the source named under it.
Exergy
The useful work potential of energy at a given state, measured against the surroundings. Energy is conserved; exergy is consumed by every real process. For a flowing stream, neglecting kinetic and potential energy:
e = (h − h0) − T0(s − s0)
Heat Q available at absolute temperature T carries exergy Q(1 − T0/T). Heat near the surroundings' temperature carries almost none.
Published evidence Çengel and Boles, glossary to chapter 8; University of Waterloo ME 354 notes, "Availability".
Dead state
The state in thermodynamic equilibrium with the environment, where exergy is zero. The usual choice is T0 = 25 °C and p0 = 1 atm (101.325 kPa); this page uses it and shows in section 05 what changes when T0 moves.
Published evidence Çengel and Boles; Waterloo ME 354 notes; da Silva et al. 2012.
Physical and chemical exergy
Physical exergy comes from a stream's temperature and pressure differing from T0 and p0; it splits into a thermal and a mechanical part. Chemical exergy comes from its composition differing from a reference environment, a defined set of reference substances proposed by Szargut. Liquid ethanol's standard chemical exergy is 1,357.7 kJ/mol, or 29.5 MJ/kg.
Published evidence Witte et al. 2022, eq. 3–5; Sciubba and Wall 2007; Szargut et al. 1988 as tabulated in TESPy 0.7.6.
Exergy destruction (Gouy–Stodola)
Gouy (1889) and Stodola (1898) independently related lost work to entropy generation. Heat transfer across a temperature difference, mixing, friction and throttling all generate entropy, and the work potential lost is
ED = T0 Sgen ≥ 0
Published evidence Sciubba and Wall 2007; Çengel and Boles; da Silva et al. 2012 ("Gouy-Stodola relation").
Exergetic efficiency
Each unit consumes a fuel exergy EF to deliver a product exergy EP; the difference is destroyed. For a whole system, losses EL also leave the boundary unused, as the cooling water and condensate do here.
ε = EP/EF · EF = EP + ED + EL
What counts as product is a choice, and it must be stated with the result.
Published evidence Witte et al. 2022, eq. 8–10 (with Tsatsaronis).
Grassmann diagram
An exergy flow diagram, named after Grassmann's 1950 work. Each flow is drawn with a width proportional to its exergy, and destruction appears as branches that end inside the units. Section 03 draws one for the example.
Published evidence Sciubba and Wall 2007, footnote 9.
03 · Worked example
In one solvent-recovery step, the evaporator and condenser destroy 79% of the steam's exergy
The system is the falling-film evaporator E-101 and the solvent condenser of the illustrative extraction train. Per batch they evaporate and condense 4,080 kg of ethanol and 2,120 kg of water. Change the inputs to see where the destruction goes.
| Input | Default | Status |
|---|---|---|
| Vapor evaporated and condensed per batch | 4,080 kg ethanol and 2,120 kg water (stream 8) | Illustrative balance, process-engineering page |
| Heating steam | Saturated, 200 kPa absolute (120.2 °C), leaves as saturated condensate | Hypothetical |
| Evaporating and condensing temperature | 50 °C, under vacuum | Hypothetical |
| Cooling water | Enters 5 K above the dead state (30 °C), leaves 10 K warmer or 5 K below the condensing temperature | Hypothetical |
| Dead state | 25 °C, 101.325 kPa, liquid water | Convention |
| Evaporator area readout | Overall coefficient 1,000 W/(m²·K), evaporation over 8 h | Hypothetical, for comparison only |
Grassmann diagram of the step Band width proportional to exergy, MJ per batch; percentages of the steam's exergy
Values at the default inputs
| Term | Energy, MJ | Exergy, MJ | % of steam exergy |
|---|---|---|---|
| Steam supplied (saturated vapor at 200 kPa) | 10,262 | 2,311 | 100.0 |
| Returned with the condensate (leaves the boundary) | 1,577 | 209 | 9.1 |
| Destroyed in the evaporator, T0·Sgen | 0 | 1,430 | 61.9 |
| Carried by the vapor to the condenser | 8,685 | 672 | 29.1 |
| Destroyed in the condenser, T0·Sgen | 0 | 391 | 16.9 |
| Leaves with the cooling water | 8,685 | 281 | 12.2 |
At these inputs the evaporator destroys 62% and the condenser 17% of the steam's exergy; the cooling water carries 12% away.
- Heat duty, evaporator and condenser
- 8,685 MJ
- Steam used
- 3,945 kg at 120.2 °C
- Exergy supplied by the steam
- 2,311 MJ
- Destroyed in the evaporator
- 1,430 MJ, 62%
- Destroyed in the condenser
- 391 MJ, 17%
- Destroyed in both units
- 79% of the steam exergy
- Evaporator exergetic efficiency
- 32%
- Step exergetic efficiency, separation plus recovered heat
- 2.0%
- Heat recovered, energy and exergy
- 0 MJ and 0 MJ (–)
- Cooling water
- 208 t, 30 to 40 °C
- Evaporator area at the stated coefficient
- 4.3 m²
The step's real product is the separation. Its minimum work, for an ideal solution at 25 °C, is 42 MJ per batch, 2.0% of the exergy the steam gives up in the evaporator, which is why the heat chain above can leave it out.
Method, assumptions and limits
What it calculates. Energy and exergy per batch for evaporating and condensing stream 8: the steam's exergy, its split into condensate, destruction in each unit, cooling water and recovered heat; the separation's minimum work; and an evaporator area for comparison.
Equations. Heat duty Q = Σi mi hfg,i(Tb) for ethanol and water. Exergy delivered to the process Ep = Σi mi(hfg,i − T0sfg,i) = Q(1 − T0/Tb). Steam ms = Q/(hg − hf); exergy in ms[(hg − h0) − T0(sg − s0)], condensate likewise with hf, sf. Evaporator destruction = steam exergy in − condensate exergy − Ep. Cooling water mcw = Q/(hout − hin) with exergy gain mcw[(hout − hin) − T0(sout − sin)]; condenser destruction = Ep − that gain. A fraction f of the condenser heat goes to a user at the same temperatures, so f of the gain counts as recovered. Minimum separation work, filtrate liquid to distillate and aqueous concentrate at T0: Wmin = RT0[nDΣx ln x − nFΣx ln x] (activity coefficients set to 1). Area A = Q/[U(Ts − Tb)t].
Variables and units. h kJ/kg, s kJ/(kg·K), temperatures in kelvin inside the equations, results in MJ per batch. Exergetic efficiency of the evaporator: product Ep, fuel = steam exergy in − condensate exergy. Efficiency of the step: product Wmin + recovered exergy, same fuel.
Assumptions. The process side boils and condenses at one temperature; latent heat only (feed already at Tb); ideal mixing, so heat of mixing and the boiling-point spread of ethanol–water are ignored; no heat losses, pressure drops, vacuum-pump work or subcooling. The boiler and the cooling tower are outside the boundary. The extract solids are ignored. The process-engineering page uses latent heats at the normal boiling points (8,200 MJ for this step); at 50 °C both latent heats are larger, giving 8,685 MJ.
Valid range. Inputs are limited to the slider ranges. The condensing temperature must exceed the cooling-water inlet by at least 8 K (3 K of warming and a 5 K approach); below that the model raises it and says so.
What it does not establish. A design, a cost, a saving, a product-quality effect or an environmental impact. Steam and electricity are not compared.
Properties. CoolProp 8.0.0 (Bell et al. 2014): water IAPWS-95 (Wagner and Pruß 2002), ethanol (Schroeder et al. 2014). Water values agree with the NIST Chemistry WebBook to the digits shown; ethanol's enthalpy of vaporization is 0.6% above NIST's tabulated 41.0 kJ/mol at 320 K and 1.3% above 38.7 kJ/mol at 351 K. Tables every 2.5 kPa and 0.5 °C, interpolated linearly.
Verification. An independent script evaluates the model directly in CoolProp, checks each destruction against T0Sgen from the entropy balance, renders the diagram with this page's own script at 193 input sets and checks every label. A second script runs the page model on 13 input sets and passes when every result agrees within 0.5%.
04 · Where destruction concentrates
Changing the vacuum moves the destruction between units without reducing it
Raising the process temperature from 50 to 80 °C cuts evaporator destruction from 1,430 to 721 MJ and raises condenser destruction from 391 to 1,030 MJ. With the cooling water fixed at 30 to 40 °C, 78.8% of the steam's exergy is destroyed at every temperature from 50 to 80 °C. At 40 °C the share rises to 81.7%, because the cooling water must leave cooler.
Steam exergy split at five process temperatures MJ per batch; steam at 200 kPa, dead state 25 °C; number above each bar: MJ destroyed in both units
Values in the chart
| Process temperature | Evaporator destroyed, MJ | Condenser destroyed, MJ | Cooling water, MJ | Condensate, MJ | Total destroyed, MJ | Evaporator area, m² |
|---|---|---|---|---|---|---|
| 40 °C | 1,706 | 205 | 215 | 212 | 1,911 | 3.8 |
| 50 °C | 1,430 | 391 | 281 | 209 | 1,821 | 4.3 |
| 60 °C | 1,175 | 624 | 278 | 207 | 1,799 | 4.9 |
| 70 °C | 939 | 836 | 274 | 204 | 1,775 | 5.9 |
| 80 °C | 721 | 1,030 | 270 | 201 | 1,751 | 7.2 |
Use the coolest steam that does the job
Steam at 150 kPa (111.3 °C) instead of 200 kPa cuts evaporator destruction from 1,430 to 1,279 MJ. It also narrows the temperature gap, so the same duty needs 4.9 m² instead of 4.3 m².
Reuse the vapor's exergy
The vapor leaves the evaporator carrying 672 MJ of exergy at 50 °C. A second effect, vapor recompression or heat integration can use part of the gap a single effect destroys; pinch analysis sets the heat-recovery target.
Condenser heat is mostly energy, little exergy
Sending half the condenser heat to a low-temperature user recovers 4,343 MJ of energy and 141 MJ of exergy, 3.2% as much. It pays only where something needs heat at about 40 °C.
Vented solvent is an exergy loss too
The 30 kg of ethanol vented per batch in the illustrative balance carry 884 MJ of chemical exergy, equal to 38% of the steam's exergy for this step. Better vent condensing may matter more than either heat exchanger.
Model of section 03; vent mass from stream 19 of the illustrative balance; ethanol 1,357.7 kJ/mol (Szargut et al. 1988, via TESPy 0.7.6) and 46.068 g/mol.
05 · Limitations
Exergy results depend on choices that must be stated with them
The reference temperature changes the answer
Moving T0 from 15 to 35 °C lowers the steam's exergy from 2,581 to 2,047 MJ and the evaporator's exergetic efficiency from 40% to 21%. Sciubba and Wall note that exergy values depend on the reference state chosen, and da Silva et al. that no standard environment fits every region. Options must be compared at one stated dead state.
| T0 | Steam exergy, MJ | Evaporator destroyed, MJ | Condenser destroyed, MJ | Evaporator ε |
|---|---|---|---|---|
| 15 °C | 2,581 | 1,382 | 650 | 40% |
| 25 °C | 2,311 | 1,430 | 391 | 32% |
| 35 °C | 2,047 | 1,478 | 197 | 21% |
A botanical extract has no tabulated chemical exergy
Standard chemical exergies exist for defined compounds such as ethanol. An extract is a mixture of many compounds, some unidentified. Correlations from elemental analysis agree with the Szargut–Styrylska correlations within about ±1.5% for solid fuels (Song et al. 2012), but they estimate a fuel-like work potential and inherit the limits of the heating-value correlations behind them. That number says nothing about an extract's quality, so this page leaves the extract out.
Less destruction usually means more equipment
Destruction in the evaporator falls as the temperature gap narrows, and the area needed grows: 7.2 m² at 80 °C against 4.3 m² at 50 °C here. Whether that pays depends on steam price, capital cost and product limits. Exergoeconomic methods attach costs to exergy flows for this trade-off (Sciubba and Wall 2007).
| Steam pressure | Steam temperature | Evaporator destroyed, MJ | Evaporator area, m² |
|---|---|---|---|
| 150 kPa | 111.3 °C | 1,279 | 4.9 |
| 200 kPa | 120.2 °C | 1,430 | 4.3 |
| 400 kPa | 143.6 °C | 1,800 | 3.2 |
Exergy is not an environmental impact score
Dewulf et al. (2008) found exergy most mature in environmental analysis as resource and efficiency accounting, and far less mature where it is coupled with economics. Sciubba and Wall call the equation "exergy discharge into the environment = pollution" incorrect in quantitative terms. Toxicity and other impacts need life-cycle assessment.
The example is a single-temperature, latent-heat model with ideal mixing and no losses, boiler or cooling tower. It shows the method and the scale of each term; it is not a design.
06 · Proposed use
Exergy would rank where to look; cost, life-cycle impact and product quality would decide
EUTECNIQ proposes to use exergy analysis to screen process options for botanical extraction, solvent recovery and drying, alongside economics and life-cycle assessment. It would never be the sole criterion for a decision.
Proposed capabilityNo client work, plant data or pilot runs exist. Pilot extraction, solvent recovery and drying are planned for Phase II of the facility plan.
- Close the balances. Mass and energy first, from the process flow diagram and stream table.
- State the frame. Dead state, system boundary, property sources, and the fuel and product of each unit.
- Rank the destruction. By unit, with a Grassmann diagram; pinch analysis for heat-recovery targets and CFD where a local flow or heat-transfer mechanism explains a loss.
- Screen the options. Exergy, cost drivers (area, steam, solvent makeup), life-cycle indicators and product limits such as maximum temperature in one table, as in the extraction decision demonstration.
- Replace the hypotheticals. Measured pilot data before any recommendation.
07 · Related methods
The same balance feeds four other analyses on this site
Process engineering and scale-up
The extraction train, its 19-stream mass balance and the energy terms this page starts from.
Read more Heat recoveryPinch analysis
How much of the process heat can be recovered between hot and cold streams before any utility is used.
Read more Local mechanismsProcess CFD and mixing
Flow and heat transfer inside one vessel, where a lumped balance cannot say why a loss occurs.
Read more DecisionThe extraction decision
Five solvent routes for one rosemary separation, compared on heat, solvent loss and published yield.
Read more ImpactSustainability and life-cycle assessment
How life-cycle assessment works and what published studies of extraction routes found.
Read more08 · Sources
References opened for this page
- Çengel YA, Boles MA. Thermodynamics: An Engineering Approach. 8th ed. McGraw-Hill; 2015. Online Learning Center, chapter 8 glossary (exergy, dead state, exergy destroyed, second-law efficiency). highered.mheducation.com/sites/0073398179
- University of Waterloo. ME 354, Thermodynamics 2: "Availability" lecture notes (flow exergy, exergy of heat, T0 = 25 °C and P0 = 1 atm). mhtlab.uwaterloo.ca/courses/me354
- Sciubba E, Wall G. A brief commented history of exergy from the beginnings to 2004. Int J Thermodyn. 2007;10(1):1–26. dergipark.org.tr/en/download/article-file/65698
- Witte F, Hofmann M, Meier J, Tuschy I, Tsatsaronis G. Generic and open-source exergy analysis: extending the simulation framework TESPy. Energies. 2022;15(11):4087. doi.org/10.3390/en15114087
- da Silva JAM, de Oliveira Junior S, Pulgarín León J, Velazquez Arredondo HI, Molina A. On the exergy determination for petroleum fractions and separation processes efficiency. Proceedings of ENCIT 2012, 14th Brazilian Congress of Thermal Sciences and Engineering; 2012. abcm.org.br/anais/encit/2012
- Szargut J, Morris DR, Steward FR. Exergy Analysis of Thermal, Chemical, and Metallurgical Processes. Hemisphere; 1988. Standard chemical exergies as tabulated in the open-source TESPy 0.7.6 dataset
tespy/data/ChemEx/Szargut1988.json(ethanol, liquid, 1,357.7 kJ/mol). pypi.org/project/tespy/0.7.6 - Song G, Xiao J, Zhao H, Shen L. A unified correlation for estimating specific chemical exergy of solid and liquid fuels. Energy. 2012;40:164–173. doi.org/10.1016/j.energy.2012.02.016
- Dewulf J, Van Langenhove H, Muys B, Bruers S, Bakshi BR, Grubb GF, Paulus DM, Sciubba E. Exergy: its potential and limitations in environmental science and technology. Environ Sci Technol. 2008;42(7):2221–2232. doi.org/10.1021/es071719a
- Larsen D, ed. Physical Chemistry (LibreTexts), section 24.9: Gibbs energy of mixing of binary solutions in terms of the activity coefficient. CC BY-NC-SA 4.0. chem.libretexts.org, section 24.9
- Bell IH, Wronski J, Quoilin S, Lemort V. Pure and pseudo-pure fluid thermophysical property evaluation and the open-source thermophysical property library CoolProp. Ind Eng Chem Res. 2014;53(6):2498–2508. doi.org/10.1021/ie4033999
- Wagner W, Pruß A. The IAPWS formulation 1995 for the thermodynamic properties of ordinary water substance for general and scientific use. J Phys Chem Ref Data. 2002;31(2):387–535. doi.org/10.1063/1.1461829
- Schroeder JA, Penoncello SG, Schroeder JS. A fundamental equation of state for ethanol. J Phys Chem Ref Data. 2014;43(4):043102. doi.org/10.1063/1.4895394
- NIST Chemistry WebBook, SRD 69: thermophysical properties of water (saturation at 200 kPa; liquid at 25 and 35 °C) and ethanol phase-change data (enthalpy of vaporization, Counsell et al. 1970). Retrieved November 1, 2026. webbook.nist.gov
Health information notice. These statements have not been evaluated by the Food and Drug Administration. Nothing on this site is intended to diagnose, treat, cure or prevent any disease, and nothing here is medical advice.
Read the full notice
The information is for general education only. It does not replace advice, diagnosis or treatment from a qualified health professional, or any medication a clinician has prescribed. Do not start, stop or change any medicine, supplement or herbal product because of something you read here. Talk to your doctor or pharmacist first, especially if you are pregnant or breastfeeding, have a medical condition, take any medicines, are preparing for surgery, or are caring for a child. Research findings, traditional uses and safety data are reported as their sources state them; they are not recommendations or claims about any product. If you think you may have a medical emergency, call your doctor or 911 at once.
EUTECNIQ Sciences sells no supplements or health products today and receives nothing from any product or ingredient mentioned on this site; any commercial interest it later has in an ingredient will be stated on that ingredient’s page.